For custom cable assemblies and wire harnesses, Aslan Sourcing offers a factory search project: we screen the Chinese factories that make assemblies like yours, visit the shortlist, negotiate in Chinese, pull samples and hand you a ready-to-order file, quoted per project. We have no standing partner factory in this category and no engineers, so you supply the drawing, the drawing is the specification, and we do not review tolerances, materials or design.

Other terms are on our pricing page. Factory visits, audits and inspections are charged at a day rate, with travel at cost. If we then manage the order, you pay a commission of 4 to 8 percent of order value, and the factory pays us nothing.

What to put in the request for quotation

A request for quotation (RFQ) gives comparable prices only when every factory prices the same assembly. Send your drawing with these lines filled in. This page gives general information and is no substitute for engineering advice.

The lines of the request for quotation, placed on a cable assembly with the jacket cut back. Your drawing fixes each one.Line drawing of a cable assembly: a connector at the left end, an overmould where the cable leaves it, the jacket with a label sleeve, then the jacket cut back to show the braid shield, a drain wire and three insulated conductors, stripped and crimped into terminals at the right end. A dimension line under the whole assembly marks the length. Numbered parts: connector, maker and part number or an approved equivalent; overmould, material, hardness, colour and moulded shape; insulation and jacket, compound and temperature rating; labelling, text, position, method and durability; shielding, foil, braid or both, with braid coverage; drain wire and how the shield terminates; conductor size in AWG, American Wire Gauge, and cross-section in mm²; strand count, number and diameter of strands; terminal part number and the terminal maker's crimp height; length, nominal, tolerance and the points measured between.123456789101ConnectorMaker and part number, or anapproved equivalent2OvermouldingMaterial, hardness, colour,moulded shape3Insulation and jacketCompound and temperature rating4LabellingText, position, method, durability5ShieldingFoil, braid or both, braid coverage6Drain wire7Conductor sizeAWG (American Wire Gauge) andcross-section in mm²8Strand countNumber and diameter of strands9Terminals and crimpPart number and the terminalmaker's crimp height10LengthNominal, tolerance, pointsmeasured betweenThe lines of the request for quotation, placed on a cable assembly with the jacket cut back. Your drawing fixes each one.Line drawing of a cable assembly: a connector at the left end, an overmould where the cable leaves it, the jacket with a label sleeve, then the jacket cut back to show the braid shield, a drain wire and three insulated conductors, stripped and crimped into terminals at the right end. A dimension line under the whole assembly marks the length. Numbered parts: connector, maker and part number or an approved equivalent; overmould, material, hardness, colour and moulded shape; insulation and jacket, compound and temperature rating; labelling, text, position, method and durability; shielding, foil, braid or both, with braid coverage; drain wire and how the shield terminates; conductor size in AWG, American Wire Gauge, and cross-section in mm²; strand count, number and diameter of strands; terminal part number and the terminal maker's crimp height; length, nominal, tolerance and the points measured between.123456789101ConnectorMaker and part number, or an approved equivalent2OvermouldingMaterial, hardness, colour, moulded shape3Insulation and jacketCompound and temperature rating4LabellingText, position, method, durability5ShieldingFoil, braid or both, braid coverage6Drain wire7Conductor sizeAWG (American Wire Gauge) and cross-section inmm²8Strand countNumber and diameter of strands9Terminals and crimpPart number and the terminal maker's crimp height10LengthNominal, tolerance, points measured between
The lines of the request for quotation, placed on a cable assembly with the jacket cut back. Your drawing fixes each one.
Line What to state Reference points
Conductor size AWG (American Wire Gauge) and cross-section in mm² Molex pairs 22 AWG with 0.324 mm², 20 AWG with 0.519 mm² and 18 AWG with 0.823 mm² (Molex)
Strand count Number and diameter of strands Crimp height is set to work across the wire stranding a terminal accepts (Molex), so stranding belongs on the drawing
Insulation and jacket Compound and temperature rating PVC (polyvinyl chloride) about −10 to +70 °C; TPE (thermoplastic elastomer) about −50 to +125 °C, blend-dependent (L-com); PUR (polyurethane) −25 to +80 °C in igus cables (igus); silicone −60 to +180 °C in one Lapp cable (Lapp). Ratings belong to a compound, so name the cable
UL style Style number, if the end product needs UL certification (UL Solutions, a testing and certification company) Style 1007: single conductor, extruded PVC, 80 °C, 300 V alternating current, 32 to 16 AWG (UL)
Shielding Foil, braid or both, braid coverage, drain wire, how the shield terminates
Connectors Maker and part number, or “approved equivalent” and who approves it
Terminals and crimp Terminal part number and the terminal maker’s crimp height
Overmoulding Material, hardness, colour, drawing of the moulded shape
Length Nominal, tolerance and the points measured between
Labelling Text, position, method, durability
Workmanship class IPC/WHMA-A-620 Class 1, 2 or 3 See below
Electrical test Continuity, shorts, insulation resistance, hi-pot voltage and dwell time Hi-pot means the dielectric withstanding voltage test
Pull test Minimum pull force per wire size Molex lists UL 486A pull-out values such as 57.9 N for 20 AWG and 89.0 N for 18 AWG
The temperature ranges this page quotes for insulation and jacket compounds, on one scale, with the 80 °C rating of UL Style 1007. Light bars are approximate. Ratings belong to a compound, so name the cable.Temperature scale from minus 70 to plus 200 degrees Celsius. PVC, polyvinyl chloride: about minus 10 to plus 70. TPE, thermoplastic elastomer: about minus 50 to plus 125, blend-dependent. PUR, polyurethane, in igus cables: minus 25 to plus 80. Silicone, in one Lapp cable: minus 60 to plus 180. UL Style 1007, single conductor extruded PVC: rated 80.PVC (polyvinyl chloride)about −10 to +70 °CTPE (thermoplastic elastomer)blend-dependentabout −50 to +125 °CPUR (polyurethane)in igus cables−25 to +80 °CSiliconein one Lapp cable−60 to +180 °CUL Style 1007single conductor, extruded PVC80 °C−50050100150200Temperature, in °CThe temperature ranges this page quotes for insulation and jacket compounds, on one scale, with the 80 °C rating of UL Style 1007. Light bars are approximate. Ratings belong to a compound, so name the cable.Temperature scale from minus 70 to plus 200 degrees Celsius. PVC, polyvinyl chloride: about minus 10 to plus 70. TPE, thermoplastic elastomer: about minus 50 to plus 125, blend-dependent. PUR, polyurethane, in igus cables: minus 25 to plus 80. Silicone, in one Lapp cable: minus 60 to plus 180. UL Style 1007, single conductor extruded PVC: rated 80.PVC (polyvinyl chloride)about −10 to +70 °CTPE (thermoplastic elastomer)about −50 to +125 °Cblend-dependentPUR (polyurethane)−25 to +80 °Cin igus cablesSilicone−60 to +180 °Cin one Lapp cableUL Style 100780 °Csingle conductor, extruded PVC−50050100150200Temperature, in °C
The temperature ranges this page quotes for insulation and jacket compounds, on one scale, with the 80 °C rating of UL Style 1007. Light bars are approximate. Ratings belong to a compound, so name the cable.

IPC/WHMA-A-620 and its three classes

IPC/WHMA-A-620 sets requirements and acceptance criteria for cable and wire harness assemblies. It is published by IPC, the electronics industry association, with WHMA, the Wiring Harness Manufacturer’s Association (WHMA). IPC describes it as covering “materials, methods, tests and acceptance criteria” for crimped and other interconnections (IPC). Cirris, a test equipment maker, summarises them (Cirris):

  • Class 1: the main requirement is that the finished assembly works.
  • Class 2: the end-use environment would typically not cause failures.
  • Class 3: continued performance or performance on demand is critical.

The class is yours to set. IPC’s rail addendum to the standard says the user or designer is responsible for identifying the class, and if the user does not document it, the manufacturer may (IPC). Write it on the drawing.

UL styles and what UL recognition of wire means

In the US, appliance wiring material (AWM) is tested and certified to UL 758, and UL Solutions lists more than 7,000 AWM styles (UL Solutions). Each style number fixes a construction and a rating. Wire certified this way is a UL Recognized component, and UL says using Recognized wiring components can help show compliance in the end product. Ask for the wire maker’s UL file number and check it in UL Product iQ, UL’s certification database.

RoHS and REACH

RoHS, the EU directive restricting hazardous substances in electrical and electronic equipment, caps lead, mercury, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers and four phthalates at 0.1 percent, and cadmium at 0.01 percent, by weight in homogeneous materials (EUR-Lex).

REACH is the EU chemicals regulation. Under its Article 33, a supplier of an article containing a substance from the candidate list of substances of very high concern above 0.1 percent weight by weight must give the recipient enough information for safe use, at least the substance’s name (EUR-Lex).

What we check at the factory

  • Connector authenticity: purchase invoices from the connector maker or its authorised distributor, matched to the lot labels on the reels.
  • Crimp height records: Molex calls crimp height a quick, non-destructive check and recommends at least five readings per set-up and a check every 250 to 500 parts.
  • Pull test records: a destructive test, with at least five readings per set-up.
  • 100 percent electrical test: every assembly on a tester programmed to your pin-out, with logs. The hi-pot test finds sudden insulation breakdowns between conductors (Cirris).
  • IPC training: how many operators and inspectors hold a current Certified IPC Specialist (CIS) credential for the standard (IPC), and whether the site is on IPC’s Qualified Manufacturers List, which records Class 1, 2 and 3 for each site.
  • RoHS and REACH declarations signed for each part number.

Our factory audit guide explains what a visit covers and costs. Before shipment, a pre-shipment inspection samples finished assemblies against your drawing.

Questions buyers ask

Do you already work with a cable assembly factory? No. Our standing factory relationships are in brushes and vacuum cleaners. For cable assemblies we run a factory search project for your part, quoted before we start.

Will you check our drawing? No. We have no engineers. The factory quotes and builds to your drawing, and we check the product against it.

Can the factory use branded connectors? Yes, if the quote names the maker’s part number and the factory shows purchase invoices. If you allow an equivalent, state who approves it.

Who owns the drawing and the overmould tooling? You do, if the contract says so. Put tooling ownership in writing and sign an NNN agreement (non-disclosure, non-use, non-circumvention) before you send drawings; see our NNN guide.

Can the housings be sourced in the same project? Moulded and machined parts follow the same factory search approach; see injection molding and CNC (computer numerical control) machining.